宿舍熱工性能指標計算及審定表.xls
下載文檔
上傳人:故事
編號:760896
2023-09-27
2頁
197KB
1、居居住住建建筑筑熱熱工工性性能能指指標標計計算算及及審審定定表表工程編號工程名稱層數 層高窗墻面積比63.3M朝向南東西北設計建筑0.270.020.040.28結構類型及主朝向框架 南北體形系數(S)0.19計算項目圍護結構傳熱量計算數據設計建筑傳熱系數限值iKiFii*Ki*Fiw/kw/k()屋頂主體部分0.950.451026.85438.98S0.30,K0.45 0.30S0.32,K0.40S0.32,K0.36陽臺頂0.950.450.000.00凸窗頂0.950.450.000.00外 墻無陽臺南0.780.550.000.00S0.28,K0.55 0.28S0.30,K02、.520.30S0.32,K0.48 S0.32,K0.36東0.890.550.000.00西0.890.550.000.00北0.930.550.000.00封閉陽臺內南0.470.551143.74295.66東、西0.540.55407.04120.89北0.560.551143.74352.27陽臺窗、凸窗上、下梁擋板南0.780.550.000.00東、西0.890.550.000.00北0.930.550.000.00外 窗有陽臺中空雙玻窗南0.652.80303.80552.922.80東、西0.812.8014.7233.382.80北0.892.80320.60798.943、2.80單玻封閉陽臺內設的中空雙玻門南0.392.800.000.002.80東、西0.492.800.000.002.80北0.542.800.000.002.80無陽臺中空雙玻窗南0.402.800.000.002.80東0.402.800.000.002.80西0.682.800.000.002.80北0.842.800.000.002.80中空雙玻封閉陽臺窗南0.402.800.000.002.80東、西0.682.800.000.002.80北0.842.800.000.002.80陽臺門下部門芯板南0.781.700.000.001.70東、西0.891.700.000.00北0.4、931.700.000.00不采暖樓梯間隔墻0.600.681002.59409.060.68戶門0.602.0037.8045.362.00地板接觸室外空氣1.000.390.000.000.40不采暖地下室上部地板0.750.430.000.000.45地面周邊1.000.30533.96160.190.30非周邊1.000.30492.89147.87變形縫南0.780.500.000.00同外墻限值東、西0.890.500.000.00北0.930.500.000.00傳熱耗熱量QH.TQH.T(ti-te)(mi=1 i*Ki*Fi)/A08.47空氣滲透耗熱量QINF樓梯間不采暖15、.891V0/A06.86樓梯間采暖2.049V0/A0建筑體積V028433.89建筑面積A07842.00內部得熱量指標QI.H3.80建筑物耗熱量指標QHQH=QH.T+QINF-QI.H11.5314.7W/耗煤量指標(Z=145d)QC=24*Z*QH/HC*n1*n28.0710.27kg/項目主持人審定意見:建筑專業設計人設備專業設計人審核人審定人 2012 年09月 日居居住住建建筑筑熱熱工工性性能能指指標標計計算算及及審審定定表表工程編號工程名稱層數層高窗墻面積比CSJ071068光華門農民安置區11#16#21#商住樓(16#樓)72.9M朝向南東西北設計建筑0.300.06、30.030.22結構類型及主朝向框剪 南北體形系數(S)0.17計算項目圍護結構傳熱量計算數據設計建筑傳熱系數限值iKiFii*Ki*Fiw/kw/k()屋頂主體部分0.950.45928.48396.93S0.30,K0.45 0.30S0.32,K0.40S0.32,K0.36陽臺頂0.950.450.000.00凸窗頂0.950.450.000.00外 墻無陽臺南0.780.551095.22469.85S0.28,K0.55 0.28S0.30,K0.520.30S0.32,K0.48 S0.32,K0.36東、西0.890.55277.41135.79北0.930.551217.47、4622.72封閉陽臺內南0.470.550.000.00東、西0.540.550.000.00北0.560.550.000.00陽臺窗、凸窗上、下梁擋板南0.780.550.000.00東、西0.890.550.000.00北0.930.550.000.00外 窗有陽臺中空雙玻窗南0.652.800.000.002.80東、西0.812.800.000.002.80北0.892.800.000.002.80單玻封閉陽臺內設的中空雙玻門南0.392.800.000.002.80東、西0.492.800.000.002.80北0.542.800.000.002.80無陽臺中空雙玻窗南0.402.8、80476.00533.122.80東、西0.682.808.8216.792.80北0.842.80333.48784.342.80中空雙玻封閉陽臺窗南0.402.800.000.002.80東、西0.682.800.000.002.80北0.842.800.000.002.80陽臺門下部門芯板南0.781.700.000.001.70東、西0.891.700.000.00北0.931.700.000.00不采暖樓梯間隔墻0.600.671248.24501.790.68戶門0.602.00117.60141.122.00地板接觸室外空氣1.000.390.000.000.40不采暖地下室上9、部地板 0.750.420.000.000.45地面周邊1.000.30482.81144.840.30非周邊1.000.30445.67133.70變形縫南0.780.500.000.00同外墻限值東、西0.890.500.000.00北0.930.500.000.00傳熱耗熱量QH.TQH.T(ti-te)(mi=1 i*Ki*Fi)/A011.65空氣滲透耗熱量QINF樓梯間不采暖1.891V0/A05.52樓梯間采暖2.049V0/A0建筑體積V019243.40建筑面積A06593.48內部得熱量指標QI.H3.80建筑物耗熱量指標QHQH=QH.T+QINF-QI.H13.3714.7W/耗煤量指標(Z=145d)QC=24*Z*QH/HC*n1*n29.3610.27kg/項目主持人審定意見:建筑專業設計人設備專業設計人審核人審定人 2010 年 8 月 日