實驗學校電氣施工(計算書).xlsx
下載文檔
上傳人:Le****97
編號:936327
2024-06-06
20頁
93.13KB
1、附附表表1 1:A1TA1T變變壓壓器器(1#1#變變電電所所)(供供:部部分分教教學學綜綜合合樓樓、地地下下室室用用電電)設備名稱設備容量(KW)需要系數KxCOStg有功功率(KW)教學樓樓層電源干線12000.60.850.62120教學樓樓層空調電源干線11600.70.850.62112教學樓樓層空調電源干線22000.70.850.62140教學樓樓層空調電源干線31500.70.850.62105教學樓樓層空調電源干線42100.70.850.62147教學樓四層空調電源箱1000.70.850.6270教學樓4層網絡控制室電源箱500.80.850.6240教學樓樓層電源電源52、1200.80.850.6296LED顯示屏電源(預留)450.80.850.6236景觀照明箱810.850.628教學樓客梯電源箱1(無機房)240.30.551.527.2生活水泵電源箱450.80.80.7536弱電機房電源箱100.80.850.628信息機房電源箱1100.80.850.6288充電樁變電房電源箱100.80.80.758合計14421021.2k=0.9/0.9919.08損耗功率10.9電容補償電容補償后14420.970.26930.0無功功率(kvar)視在功率(KVA)變壓器容量(KVA)負荷率計算電流備注74.469.4486.865.191.1443.3、424.859.5222.324.9610.944274.9654.566645.344580.811087.254.36-390245.17961.7312500.771461.24附附表表2 2:A2TA2T變變壓壓器器(1#1#變變電電所所)(供供:部部分分教教學學綜綜合合樓樓、地地下下室室用用電電)設備名稱設備容量(KW)需要系數KxCOStg教學樓樓層電源干線21750.70.850.62教學樓樓層電源干線32600.70.850.62教學樓樓層空調電源干線52500.70.850.62教學樓樓層空調電源干線61900.70.850.62教學樓樓層空調主機電源箱7540.70.8504、.62教學樓室外潛水泵電源箱100.80.80.75下沉庭院電源箱300.80.80.75教學綜合樓普通風機電源箱50.80.80.75亮化照明電源500.80.850.62教學樓走道照明電源干線1150.80.850.62教學樓走道照明電源干線2150.80.850.62教學樓走道照明電源干線3150.80.850.62地下室普通照明電源總箱2400.80.850.62事故風機電源箱50.80.80.75教學樓應急照明消防電源配電總箱130.80.850.62教學樓應急照明消防電源配電總箱230.80.850.62教學樓應急照明消防電源配電總箱330.80.850.62應急照明電源總箱1125、0.80.850.62變配電房電源箱1100.80.850.62消防泵房照明電源箱50.80.850.62人防電源總箱31350.50.850.62消控中心電源100.80.850.62安防電源200.80.850.62發電機房電源箱50.80.80.75消防水泵電源箱1195000消防水泵電源箱2150000教學樓防火卷簾電源干線210000教學樓防火卷簾電源干線310000地下一層防火分區1消防兼平時風機電源干線220.50.80.75地下室防火分區3消防兼平時風機電源總箱1420.50.80.75地下室防火分區4消防兼平時風機電源總箱1360.50.80.75地下室防火分區5消防兼平時風6、機電源總箱1750.50.80.75合計1860k=0.9/0.9損耗功率電容補償電容補償后18600.970.26舞臺電源箱300.80.850.62有功功率(KW)無功功率(kvar)視在功率(KVA)變壓器容量(KVA)負荷率計算電流備注122.575.95182112.84175108.513382.4637.823.436862418434024.8127.44127.44127.443219.84432.41.4882.41.4882.41.4889.65.95284.9642.4867.541.8584.96169.924300000000118.252115.751813.537、7.528.1251010.1643.357909.09579.021077.810.853.89-390919.9242.91951.4012500.761445.552414.88附附表表3 3:A3TA3T變變壓壓器器(1#1#變變電電所所)(供供:充充電電樁樁用用電電)設備名稱設備容量(KW)需要系數KxCOStg有功功率(KW)無功功率(kvar)視在功率(KVA)變壓器容量(KVA)負荷率計算電流備注充電樁電源箱11800.70.80.7512694.5快充4臺充電樁電源箱21800.70.80.7512694.5快充4臺充電樁電源箱31800.70.80.7512694.5快充48、臺充電樁電源箱41260.70.80.7588.266.15慢充18臺充電樁電源箱51260.70.80.7588.266.15慢充18臺合計792554.4415.8k=0.8/0.8443.52332.64554.4損耗功率5.527.72電容補償-210電容補償后7920.950.33449.1150.36473.576300.75719.53快充12臺慢充36臺16161616160附附表表4 4:B1TB1T變變壓壓器器(2#2#變變電電所所)(供供:部部分分教教學學綜綜合合樓樓、宿宿舍舍樓樓、教教工工食食堂堂、多多功功能能廳廳、幼幼兒兒園園用用電電)設備名稱設備容量(KW)需要系數9、KxCOStg有功功率(KW)無功功率(kvar)視在功率(KVA)變壓器容量(KVA)負荷率計算電流1#宿舍樓樓層電源干線11780.50.850.628955.181#宿舍樓樓層電源干線22600.50.850.6213080.63#宿舍樓樓層電源干線12880.50.850.6214489.283#宿舍樓樓層電源干線22160.50.850.6210866.963#宿舍樓樓層電源干線33870.50.850.62193.5119.97多功能廳屋頂風冷熱泵電源箱2550.80.80.75204153多功能廳舞臺預留電源箱1200.70.850.628452.08廚房動力電源箱31800.310、0.850.625433.482#宿舍普通風機電源箱200.70.80.751410.53#宿舍樓室外潛水泵電源箱100.80.80.7586幼兒園廚房用電1500.30.850.624527.9幼兒園電源總箱1800.70.850.6212678.121#宿舍客梯電源箱1290.30.551.528.713.2242#宿舍客梯電源箱290.30.551.528.713.224合計23021216.9799.518k=0.8/0.8973.52639.611164.8損耗功率11.658.24電容補償-390電容補償后23020.950.31985.2307.861032.1512500.8311、1568.23備注充電樁96臺0附附表表5 5:B2TB2T變變壓壓器器(2#2#變變電電所所)(供供:部部分分教教學學綜綜合合樓樓、宿宿舍舍樓樓、教教工工食食堂堂、多多功功能能廳廳、幼幼兒兒園園用用電電)設備名稱設備容量(KW)需要系數KxCOStg2#宿舍樓層電源干線12000.50.850.622#宿舍樓層電源干線21900.50.850.622#宿舍樓層電源干線32520.50.850.62廚房動力電源箱12160.30.850.621#宿舍屋頂排油煙風機電源箱500.70.80.75多功能廳游泳館電源箱350.70.850.62籃球館電源箱300.70.850.62(地下室)泳池機房12、電源箱1350.70.80.75景觀電源箱1790.70.850.62景觀電源箱21580.70.850.62廚房動力電源箱21470.30.850.62多功能廳空調電源總箱500.80.80.75多功能廳 舞臺預留電源箱1350.80.850.62多功能廳 風冷熱泵電源箱138.50.80.850.623#宿舍客梯電源箱410.30.551.52廚房動力電源箱41810.30.80.75餐梯電源箱50.30.551.52一層廚房照明電源箱300.70.850.621#宿舍走道照明電源干線1200.60.850.622#宿舍走道照明電源干線200.60.850.623#宿舍走道照明電源干線2013、0.60.850.62地下室普通照明電源總箱1350.60.850.621#宿舍消防電梯電源箱1170.30.551.522#宿舍消防電梯電源箱170.30.551.523#宿舍消防電梯電源箱170.30.551.521#宿舍應急照明消防電源配電總箱150.60.850.622#宿舍應急照明消防電源配電總箱150.60.850.623#宿舍應急照明消防電源配電總箱150.60.850.62多功能廳應急照明消防電源配電總箱150.60.850.62應急照明電源總箱3120.60.850.62變配電房電源箱2100.80.850.62人防電源總箱12880.250.850.62公共開關房電源箱1014、0.80.850.621#宿舍樓消防風機電源箱7.70002#宿舍樓消防風機電源干線120003#宿舍消防風機電源干線55000多功能廳頂消防風機電源箱66000地下一層防火分區7消防兼平時風機電源干線210.30.80.75地下室防火分區9消防兼平時風機電源總箱1230.30.80.75地下一層防火分區10消防兼平時風機電源干線190.30.80.75合計2662.2k=0.8/0.8損耗功率電容補償電容補償后2662.20.950.33有功功率(KW)無功功率(kvar)視在功率(KVA)變壓器容量(KVA)負荷率計算電流備注100629558.912678.1264.840.17635215、6.2524.515.192113.0294.570.87555.334.286110.668.57244.127.342403010866.9630.819.09612.318.69654.340.7251.52.282113.02127.44127.44127.442113.025.17.7525.17.7525.17.75231.8631.8631.8631.867.24.46484.967244.6484.96000000006.34.7256.95.1755.74.2751237.1824.743989.68659.791189.511.959.47-3901001.6329.27116、054.3112500.841601.90附附表表6 6:發發電電機機(非非火火警警時時停停市市電電)(供供:教教學學綜綜合合樓樓、宿宿舍舍樓樓、教教工工食食堂堂、多多功功能能廳廳、幼幼兒兒園園、地地下下室室用用電電)設備名稱設備容量(KW)需要系數KxCOStg有功功率(KW)發電機容量(KVA)負荷率計算電流備注1#宿舍客梯電源箱1290.30.551.528.72#宿舍客梯電源箱290.30.551.528.73#宿舍客梯電源箱410.30.551.5212.3廚房動力電源箱41810.30.80.7554.3餐梯電源箱50.30.551.521.5一層廚房照明電源箱300.90.85017、.6227二層廚房照明電源箱10.80.90.850.629.721#宿舍走道照明電源干線1200.70.850.62142#宿舍走道照明電源干線200.70.850.62143#宿舍走道照明電源干線200.70.850.6214地下室普通照明電源總箱1350.70.850.6224.51#宿舍消防電梯電源箱1170.30.551.525.12#宿舍消防電梯電源箱170.30.551.525.13#宿舍消防電梯電源箱170.30.551.525.11#宿舍應急照明消防電源配電總箱150.80.850.6242#宿舍應急照明消防電源配電總箱150.80.850.6243#宿舍應急照明消防電源配電18、總箱150.80.850.624多功能廳應急照明消防電源配電總箱150.80.850.624應急照明電源總箱3120.80.850.629.6變配電房電源箱2100.80.850.628人防電源總箱12880.30.850.6286.4公共開關房電源箱100.80.850.628教學樓客梯電源箱1(無機房)240.30.551.527.2生活水泵電源箱450.80.80.7536弱電機房電源箱100.80.850.628信息機房電源箱1100.80.850.6288充電樁變電房電源箱100.80.80.758教學樓走道照明電源干線1150.70.850.6210.5教學樓走道照明電源干線21519、0.70.850.6210.5教學樓走道照明電源干線3150.70.850.6210.5地下室普通照明電源總箱2400.70.850.6228事故風機電源箱50.80.80.754教學樓應急照明消防電源配電總箱130.80.850.622.4教學樓應急照明消防電源配電總箱230.80.850.622.4教學樓應急照明消防電源配電總箱330.80.850.622.4應急照明電源總箱1120.80.850.629.6變配電房電源箱1100.80.850.628消防泵房照明電源箱50.80.850.624人防電源總箱31350.30.850.6240.5消控中心電源100.80.850.628安防電20、源200.80.850.6216發電機房電源箱50.80.80.754合計1306.8640.02k=0.9576.0181306.8576.06500.89875.19附附表表7 7:發發電電機機(火火警警時時停停市市電電)(供供:教教學學綜綜合合樓樓、宿宿舍舍樓樓、教教工工食食堂堂、多多功功能能廳廳、幼幼兒兒園園、地地下下室室用用電電)設備名稱設備容量(KW)需要系數KxCOStg有功功率(KW)發電機容量(KVA)負荷率計算電流備注1#宿舍消防電梯電源箱1170.30.551.525.12#宿舍消防電梯電源箱170.30.551.525.13#宿舍消防電梯電源箱170.30.551.5221、5.11#宿舍應急照明消防電源配電總箱150.60.850.6232#宿舍應急照明消防電源配電總箱150.60.850.6233#宿舍應急照明消防電源配電總箱150.60.850.623多功能廳應急照明消防電源配電總箱150.60.850.623應急照明電源總箱3120.60.850.627.2變配電房電源箱2100.80.850.628公共開關房電源箱100.80.850.628教學樓應急照明消防電源配電總箱130.60.850.621.8教學樓應急照明消防電源配電總箱230.60.850.621.8教學樓應急照明消防電源配電總箱330.60.850.621.8應急照明電源總箱1120.6022、.850.627.2變配電房電源箱1100.80.850.628消防泵房照明電源箱50.80.850.624消控中心電源100.80.850.628安防電源200.80.850.6216發電機房電源箱50.80.80.754消防水泵電源箱119510.80.75195消防水泵電源箱215010.80.75150教學樓防火卷簾電源干線2100000教學樓防火卷簾電源干線3100000教學樓消防風機電源干線1100000教學樓消防風機電源干線250000地下一層防火分區1消防兼平時風機電源干線220000地下室防火分區3消防兼平時風機電源總箱1420.80.80.7533.6地下室防火分區4消防兼23、平時風機電源總箱1360.80.80.7528.8地下室防火分區5消防兼平時風機電源總箱1750.80.80.75601#宿舍樓消防風機電源箱7.700002#宿舍樓消防風機電源干線1200003#宿舍消防風機電源干線550000多功能廳屋頂消防風機電源箱660000地下一層防火分區7消防兼平時風機電源干線210000地下室防火分區9消防兼平時風機電源總箱1230000地下一層防火分區10消防兼平時風機電源干線190000合計932.7570.5k=1570.5932.7570.57000.82866.81發電機校驗:2.3*90+(570.5-90)=687.5KW700KW,所以選擇PH=700KW的發電機滿足要求。最大著火點:地下室防火分區5687.5
CAD圖紙
上傳時間:2023-11-22
41份