1、We will continue to improve the companys internal control system, and steady improvement in ability to manage and control, optimize business processes, to ensure smooth processes, responsibilities in place; to further strengthen internal controls, play a control post independent oversight role of ev
2、aluation complying with third-party responsibility; to actively make use of internal audit tools detect potential management, streamline, standardize related transactions, strengthening operations in accordance with law. Deepening the information management to ensure full communication zero resistan
3、ce. To constantly perfect ERP, and BFS+, and PI, and MIS, and SCM, information system based construction, full integration information system, achieved information resources shared; to expand Portal system application of breadth and depth, play information system on enterprise of Assistant role; to
4、perfect daily run maintenance operation of records, promote problem reasons analysis and system handover; to strengthening BFS+, and ERP, and SCM, technology application of training, improve employees application information system of capacity and level. Humanistic care to ensure zero. To strengthen
5、ing Humanities care, continues to foster company wind clear, and gas are, and heart Shun of culture atmosphere; strengthening love helped trapped, care difficult employees; carried out style activities, rich employees life; strengthening health and labour protection, organization career health medic
6、al, control career against; continues to implementation psychological warning prevention system, training employees health of character, and stable of mood and enterprising of attitude, created friendly fraternity of Humanities environment. To strengthen risk management, ensure that the business of
7、zero risk. To strengthened business plans management, will business business plans cover to all level, ensure the business can control in control; to close concern financial, and coal electric linkage, and energy-saving scheduling, national policy trends, strengthening track, active should; to imple
8、mentation State-owned assets method, further specification business financial management; to perfect risk tube control system, achieved risk recognition, and measure, and assessment, and report, and control feedback of closed ring management, improve risk prevention capacity. To further standardize
9、trading, and strive to achieve according to law, standardize and fair. Innovation of performance management, to ensure that potential employees zero fly. To strengthen performance management, process control, enhance employee evaluation and levels of effective communication to improve performance ma
10、nagement. To further quantify and refine employee standards . Work, full play party, and branch, and members in five type Enterprise construction in the of core role, and fighting fortress role and pioneer model role; to continues to strengthening four good leadership construction, full play levels
11、cadres in enterprise development in the附件1防止高處墜落措施檢查表 工程名稱層數/面積施工單位形象進度檢查項目檢查內容自查自糾情況工地自檢企業復檢監理檢查腳 手 架專項施工方案內腳手架是否編制專項方案,并經有效審批,監理審核;施工方案能否指導施工。架體與建筑結構拉結架體是否按照規范要求的高度、寬度與建筑結構拉結;拉結是否牢固。腳手架材質腳手架材質是否符合規范要求。(18米以下的單層廠房內裝飾腳手架可放寬至雙排竹腳手架)立桿基礎、桿件間距與剪刀撐立桿基礎是否平實,是否設置掃地桿;桿件間距是否符合方案及規范要求;剪刀撐設置及角度是否符合要求。腳手板與防護欄桿
12、腳手板是否有滿鋪,架體外側是否掛設密目式安全網;施工平橋是否設置防護欄桿。通道及架體內封閉是否按要求設置上、下施工梯;出入口是否設置擋板;腳手架是否按要求進行內封閉。交底與驗收腳手架搭設是否對工人進行安全教育及安全技術交底,是否有進行量化驗收。三寶、四口高處作業專項施工方案鋼結構安裝是否有編制專項方案,并經有效審批;高度超過2m的操作平臺及卸料平臺是否有編制專項施工方案并經有效審批;各專項施工方案能否指導施工。作業人員教育高處作業人員是否有進行針對性的安全教育及技術交底,并履行好簽字手續。卸料平臺卸料平臺搭設是否符合設計要求;卸料平臺支撐系統與腳手架應分離;卸料平臺要有限定荷載標牌。操作平臺操
13、作平臺的搭設是否符合方案要求;操作平臺是否穩固;腳手板是否滿鋪。臨邊是否設置1.2m高防護欄桿和踢腳板。鋼結構廠房高處作業設施高處作業安全防護設施是否與專項方案要求一致;有否設置安全防護鋼絲(或安全繩);是否設置安全平網;是否設置上、下施工梯。安全防護用品高處作業人員是否正確使用安全防護用品,如安全帽、安全帶等。樓梯口、電梯井口、預留洞口和坑口防護每一處應有防護措施,并形成定型化、工具化;電梯井內每隔兩層(不大于10m)應設一道平網。陽臺、樓板、屋面臨邊防護每一處臨邊應有防護措施,防護符合要求;三寶四口是否有專項施工方案。施工項目部自檢:檢查人簽名:時間:施工企業復檢:檢查人簽名:時間: (蓋
14、章)項目監理部門檢查及監督整改:檢查人簽名:時間:注:自查自糾情況需詳細填寫存在問題內容和整改落實情況工程監理單位安全管理檢查表工程名稱: 監理單位: 項目總監:序號項 目檢 查 內 容標準分得分1人員情況總監(總監代表)1、 甲方反映及現場檢查總監是否到位。 是否2、檢查工地例會紀錄。共查次,到位次,到位率%5專業監理工程師及監理員1、甲方反映及現場檢查專業監理工程師及監理員是否到位。 是否2、檢查有關的監理紀錄,根據工程進度檢查專業監理工程師及監理員是否到位。 共查次,到位次3、專業監理工程師人,持證人。4、是否設立安全監理機構或配備安全監理人員。 是否52監理規劃監理細則1、監理規劃是否
15、經總監簽字、公司技術負責人審批; 是否2、是否有施工現場安全生產專項監理制度或安全監理細則。 是否3、是否在監理細則中制定對施工單位安全技術措施的檢查方案。 是否53安全監理旁站方案對關鍵工序、關鍵部位、高危作業、易發生安全事故的薄弱環節等工程(深基坑、高大模板、施工起重機械、腳手架、吊裝工程等)是否編制專項安全監理旁站方案并按方案進行監理。 是否54施工組織設計(專項施工方案)1、是否按規定對施工組織設計中安全技術措施、專項施工方案進行審查,并按規定組織專項驗收。是否對變更后的施工組織設計安全技術措施或專項施工方案進行審查。是否2、對施工單位未按審查后的施工組織設計、專項施工方案進行施工的,
16、監理單位是否提出整改要求。 是否 55跟蹤落實情況是否對施工企業執行建筑施工安全檢查標準(JGJ59-99)情況實施監理,對存在安全隱患履行監理責任。 是否10對嚴重危及工程和人員安全的作業和設備的使用,是否及時發出停工(停用)指令,并通知建設單位和及時向有關主管部門報告。 是否 5對發出的整改通知書,是否跟蹤整改落實情況,或者施工企業拒不整改,是否及時向有關主管部門報告。 是否56定期檢查是否對施工現場進行定期和專項安全檢查,并做好安全檢查記錄。 是否 5是否對重要施工環節和安全事故易發工序進行巡查和記錄。 是否37監理資料有否按監理規劃召開監理例會,監理例會是否有安全方面的內容。 是否3施
17、工現場安全施工監理記錄是否齊全,監理月報是否能如實反映工地安全生產管理狀況。是否有記錄規范、真實、完整的安全施工監理日志。 是否5是否按規定使用廣東省建筑施工安全管理資料統一用表,建立安全監理檔案。 是否3廣東省建筑施工安全管理資料統一用表中的安全警示標志檢查表、設備驗收表(井架物料提升機、外用電梯、塔吊等)、設施驗收表(腳手架、模板、臨邊洞口、臨時用電等)是否齊全。 是否58施工企業及人員的審查情況對未辦理施工許可(或開工報告)或施工單位(含分包單位)無安全生產許可證而擅自開工的工程項目,是否及時作出停工處理,并及時上報工程所在地建設行政主管部門或安監站。 是否3是否對項目經理、專職安全員到
18、位及安全考核合格情況進行檢查。 是否5有否對電工、焊工、架子工、起重機械工、塔吊司機及指揮人員、垂直運輸設備安裝拆卸工及司機、爆破工等特種作業人員資格進行審查。 是否5是否對施工企業安全生產保證體系、安全生產責任制、各項規章制度進行審核。 是否3是否對工人的教育情況進行檢查。 是否59安全防護、文明施工措施費是否按規定對安全防護、文明施工措施費用的列支和使用實施監理。 是否510施工企業應急救援預案的建立和落實是否審核施工企業應急救援預案并督促施工企業進行演練。 是否5總體評價檢查人員(簽名): 檢查日期: 年 月 日合計注:1、總體評價 優:85-100分,良:71-84分,中:60-70分
19、,差:60分以下。2、施工現場評分差的,總體評價不能評為優、良。施工現場安全生產檢查表工程名稱: 施工單位: 項目經理:項目分類序號檢查項目檢查情況評分標準該項得分(一)管理制 度1安全生產責任制的建立及落實情況已經建立安全生產責任制,內容齊全,責任明確落實到人,簽訂人符合要求。5已經建立安全生產責任制,責任未完全落實到人。3未完善安全生產責任制度。02安全文明施工方案制定及落實情況制定安全文明施工方案,并已認真組織落實。5制定安全文明施工方案,基本落實。3未制定安全文明施工方案或未落實。03重大事故應急預案制定、演練情況及現場危險源公示、監控情況按規定編制生產安全事故應急預案,并按規定組織演
20、練;在施工現場公示重大危險源,并落實專人管理。5基本按規定編制生產安全事故應急預案,演練基本達到要求;在施工現場公示重大危險源,落實專人管理。3未按規定編制生產安全事故應急救援預案,并按規定組織演練;或未在施工現場公示重大危險源,并落實專人管理。04在建工程項目施工組織設計中的安全技術措施制定執行情況,危險性較大工程專項施工方案制定執行情況按照要求和規范編制安全技術措施,對危險性較大的分部分項工程按規定編制專項施工方案,并且該方案經施工單位技術負責人、總監理工程師簽字后實施。5未按照要求和規范編制安全技術措施,或對危險性較大的分部分項工程未按規定編制專項施工方案,或專項施工方案未經施工單位技術
21、負責人、總監理工程師簽字后實施。05作業人員及新進場、轉崗人員進入施工現場安全教育培訓情況對所有作業人員及新進場、轉崗人員進入施工現場進行有針對性的安全教育培訓。5對大部分作業人員及新進場、轉崗人員進入施工現場進行有針對性的安全教育培訓。3未對作業人員及新進場、轉崗人員進入施工現場進行有針對性的安全教育培訓。0(二)人員配備、證書6專職安全生產管理人員配備情況(持有C證)項目經理取得安全生產考核合格證書,配備足夠數量的專職安全生產管理人員。5項目經理取得安全生產考核合格證書,配備了專職安全生產管理人員,但數量不符合有關規定。3項目經理未取得安全生產考核合格證書,或未配備專職安全生產管理人員。0
22、7特種作業人員持證上崗情況特種作業人員經過專門的安全作業培訓,持證上崗。 5特種作業人員未經過專門的安全作業培訓,未取得資格證書即上崗作業。0(三)安全防護及文明施工措施費用8安全防護、文明施工措施費用使用情況安全防護、文明施工措施費用足額投入并及時支付到位。5安全防護、文明施工措施費用足額投入,支付基本到位。3安全防護、文明施工措施費用不到位,或挪作他用。0(四)市場行 為9在建工程項目施工許可、質量安全監督手續辦理情況施工許可、質量安全監督手續齊全。5未辦理施工許可或質量安全監督手續。010是否存在無證施工、越級承包、非法轉包及違法分包等問題不存在無證施工、越級承包、非法轉包及違法分包等問
23、題。5總承包單位不具備相應的施工資質或無安全生產許可證擅自施工作業;或把整體工程或主體工程轉包;或將專業工程不依法分包。0(五)現場管 理(五)現場管 理11安全防護用具配備及使用情況按照要求配備齊全、合格的安全防護用具并正確使用。5基本按照要求配備安全防護用具,并按要求使用。3沒有按照要求配備安全防護用具或未正確使用。012危險性較大工程管理情況按照佛山市深基坑與高大模板工程施工質量安全管理辦法(試行)要求對危險性較大工程進行施工。5基本按照佛山市深基坑與高大模板工程施工質量安全管理辦法(試行)要求對危險性較大工程進行施工。3沒有按照佛山市深基坑與高大模板工程施工質量安全管理辦法(試行)要求
24、對危險性較大工程進行施工。013建筑起重機械設備安拆方案制定和實施、安拆人員資格等情況安拆單位及人員具備相應資質,按照要求制定和實施建筑起重機械設備安拆方案,并按照安拆方案進行拆除。5安拆單位及人員具備相應資質,基本按照要求安拆建筑起重機械設備。3施工起重設備由不具備起重設備安裝專業承包企業資質的企業安裝或未經有相應資質的檢驗檢測機構檢驗合格。或沒有按照要求制定建筑起重機械設備安拆方案或未按照安拆方案進行拆除。014安全防護情況(包括整體提升架、臨邊洞口防護、施工用吊籃、物料提升機、卸料平臺、基坑與土方支護等)按照規范和要求進行安全防護。10基本按照規范和要求進行安全防護。6沒有按照規范和要求
25、進行安全防護。015施工臨時用電及施工機具的安全使用情況(包括三級配電兩級保護、漏電保護器、電鋸、電刨、鋼筋切斷機、鋼筋彎曲機、卷揚機、攪拌機等)施工臨時用電及施工機具的使用符合相應的標準規范。10施工臨時用電及施工機具的使用基本符合相應的標準規范。6施工臨時用電及施工機具的使用不符合相應標準規范。016施工用安全網、鋼管、扣件是否具有檢驗證明;承重支撐架體系的搭設是否符合規范要求施工用安全網、鋼管、扣件有檢驗證明;承重支撐架體系符合規范要求。10施工用安全網、鋼管、扣件有檢驗證明基本齊全;承重支撐架體系符合規范要求。6施工用安全網、鋼管、扣件有檢驗證明不齊全;承重支撐架體系不符合規范要求。0
26、17生活區及辦公區設施使用情況(包括職工食堂、宿舍、廁所、辦公室等設施)以及使用臨時圍墻的搭設情況職工食堂、廁所、飲水、浴室、生活垃圾處理、辦公區以及臨時圍墻的搭設完全符合有關標準規范的要求。5職工食堂、廁所、飲水、浴室、生活垃圾處理、辦公區以及臨時圍墻的搭設基本符合有關標準規范的要求。3職工食堂、廁所、飲水、浴室、生活垃圾處理、辦公區以及臨時圍墻的搭設違反有關標準規范的要求。0總體評價檢查人員(簽名): 檢查日期: 年 月 日 分注:1、總體評價 優:85-100分,良:71-84分,中:60-70分,差:60分以下。2、檢查時,先檢查現場再檢查資料。仿佛頃刻間,亞運就來到了我們身邊。一個普
27、通的人,很難想象它背后隱藏著多少人的心血,藏匿著多少人的汗水,背負著多少人的夢想,寄托了多少人的祝愿,在這個激動人心的時刻,在這個萬眾矚目的地方of backbone backbone role; to full strengthening members youth work, full play youth employees in company development in the of force role; to improve independent Commission against corruption work level, strengthening on enterp
28、rise business key link of effectiveness monitored. , And maintain stability. To further strengthen publicity and education, improve the overall legal system. We must strengthen safety management, establish and improve the education, supervision, and evaluation as one of the traffic safety management
29、 mechanism. To conscientiously sum up the Olympic security controls, promoting integrated management to a higher level, higher standards, a higher level of development. Employees, today is lunar calendar on December 24, the ox Bell is about to ring, at this time of year, we clearly feel the pulse of
30、 the XX power generation company to flourish, to more clearly hear XX power generation companies mature and symmetry breathing. Recalling past one another across a railing, we are enthusiastic and full of confidence. Future development opportunities, we more exciting fight more spirited. Employees,
31、let us together across 2013 full of challenges and opportunities, to create a green, low-cost operation, full of humane care of a world-class power generation company and work hard! The occasion of the Spring Festival, my sincere wish that you and the families of the staff in the new year, good heal
32、th, happy, happy17佛山市深基坑工程施工質量安全檢查表工程名稱:施工單位: 項目經理:監理單位: 項目總監:序號項目檢查內容1專項施工方案編制與審 查是否編制專項施工方案。是 否2是否包括支護、支撐系統的結構設計(包括結構選型及其計算依據;結構變形、位移和沉降觀測的允許值以及臨界狀態報警值;結構設計的安全有效使用期)。是 否3是否包括施工工藝要求,施工程序和施工進度安排。是 否4是否包括對設計要求及施工現場情況的監測控制措施。是 否5是否包括各階段施工安全措施及安全生產事故應急救援預案措施。是 否6施工單位技術負責人、總監理工程師是否審核簽字。是 否7專項施工方案專家論證審查是
33、否已組織專家對方案進行論證審查。是 否8專家是否從市專家庫中選取。是 否9論證程序是否符合要求。是 否10施工單位技術負責人、總監理工程師是否簽字批準。是 否11建 設單 位施工前,是否向施工單位提供施工現場及毗鄰區域內真實、準確、完整的地下管線資料,氣象和水文觀測資料,相鄰建筑物和構筑物、地下工程的有關資料。是 否12施工前,是否組織監理和監測單位,對鄰近建(構)筑物的現狀進行周密的調查、測繪或攝像,并作好詳細記錄。是 否13長期暴露或超過支護設計安全期而危及周邊環境安全的深基坑,是否主動回填。是 否14編制工程概算時,是否確定單項工程安全作業環境及安全施工措施所需費用。是 否15是否迫使承
34、包方以低于成本的價格競標;是否任意壓縮合理工期;是否明示或暗示設計單位或施工單位違反技術標準,降低工程質量;是否指定或隨意減少監測項目。是 否是 否是 否是 否16施 工單 位是否嚴格依照經批準的專項施工方案和國家(省)有關規定進行組織施工。是 否17施工單位技術負責人及安全負責人或其委托人、項目經理是否參加驗收,并在驗收記錄上簽字。是 否18是否就有關的安全施工技術向施工作業班組、作業人員作詳細的安全技術交底,并雙方簽字確認。是 否19是否及時有效地對工程進行監測,并作詳細記錄。是 否20是否根據安全生產事故應急救援預案組織針對性的演練。是 否21是否把深基坑工程作為本工程的重大危險源在工地
35、明顯位置進行公示。是 否22監 理單 位是否根據工程實際提出監理意見,對專項方案編寫監理規劃和實施細則。是 否23技術負責人或其委托人、總監是否參加深基坑的驗收,并在驗收記錄上簽字。是 否24工程出現險情或發生安全事故時,是否下達暫停令是否向建設主管等有關部門報告。是 否25監 督管 理區建設局是否把該工程作為本地區的重大危險源予以公示。是 否26按規定程序具備開工條件的深基坑工程,區安監站是否按要求在10天內填寫快報表上報至區建設局和市安監站。是 否27質量、安全監督站是否對該工程辦理專項登記;登記資料是否齊全。是 否28質量、安全監督站是否有針對性地編制監督計劃;在開工前是否對項目經理、總
36、監等人員進行監督交底。是 否是 否29區質量監督站是否將專項施工方案中的結構設計及專家審查論證、基坑支護工程的質量檢測和驗收、基坑開挖各階段的驗收、基坑變形控制觀測、高大模板及其支架的承載能力、剛度和穩定性等列為重點監督內容。是 否30區安全監督站應將經論證的專項施工方案中有關安全施工技術監控措施的落實、基坑工程的施工準備評價和達標評價、高大模板專項工程安全檢查評分和分項驗收等列為重點監督內容是 否31深基坑工程監督檢查每月是否不少于1次。是 否32現 場安全隱患的檢查及整改情況檢查人員簽名檢查日期佛山市高大模板工程施工質量安全檢查表工程名稱:施工單位: 項目經理:監理單位: 項目總監:序號項
37、目檢查內容1專項施工方案編制與審 查是否編制專項施工方案。是 否2是否包括支護、支撐系統的結構設計(包括結構選型及其計算依據;結構變形、位移和沉降觀測的允許值以及臨界狀態報警值;結構設計的安全有效使用期)。是 否3是否包括施工工藝要求,施工程序和施工進度安排。是 否4是否包括對設計要求及施工現場情況的監測控制措施。是 否5是否包括各階段施工安全措施及安全生產事故應急救援預案措施。是 否6施工單位技術負責人、總監理工程師是否審核簽字。是 否7專項施工方案專家論證審查是否已組織專家對方案進行論證審查。是 否8專家是否從市專家庫中選取。是 否9論證程序是否符合要求。是 否10施工單位技術負責人、總監
38、理工程師是否簽字批準。是 否11建 設單 位編制工程概算時,是否確定單項工程安全作業環境及安全施工措施所需費用。是 否12是否任意壓縮合理工期。是否明示或暗示設計單位或施工單位違反技術標準,降低工程質量。是否指定或隨意減少監測項目。是 否是 否是 否13施 工單 位是否嚴格依照經批準的專項施工方案和國家(省)有關規定進行組織施工。是 否14施工單位技術負責人及安全負責人或其委托人、項目經理是否參加驗收,并在驗收記錄上簽字。是 否15混凝土澆灌前,是否將驗收記錄送達質量和安全監督站的項目監督負責人,并告知澆灌時間。是 否16高大模板工程在澆灌混凝土時,是否委派專人全過程在現場監控支撐體系的安全。
39、是 否17項目經理是否在正澆灌混凝土的樓面上帶班檢查,并形成檢查記錄。是 否18是否就有關的安全施工技術向施工作業班組、作業人員作詳細的安全技術交底,并雙方簽字確認。是 否19是否及時有效地對工程進行監測,并作詳細記錄。是 否20是否根據安全生產事故應急救援預案措施組織針對性的演練。是 否21是否把高大模板工程作為本工程的重大危險源在工地明顯位置進行公示。是 否22監 理單 位是否根據工程實際提出監理意見,對專項方案編寫監理規劃和實施細則。是 否23技術負責人或其委托人、總監是否參加深基坑和高大模板的驗收,并在驗收記錄上簽字。是 否24高大模板工程在澆灌混凝土時,總監是否委派專人全過程在現場監
40、控支撐體系的安全;總監是否在正澆灌混凝土的樓面上帶班檢查,并形成檢查記錄。是 否是 否25工程出現險情或發生安全事故時,是否下達暫停令是否向建設主管等有關部門報告。是 否26監 督管 理區建設局是否把該工程作為本地區的重大危險源予以公示。是 否27按規定程序具備開工條件的高大模板工程,區安監站是否按要求在10天內填寫快報表上報至區建設局和市安監站。是 否28質量、安全監督站是否對該工程辦理登記;登記資料是否齊全。是 否29質量、安全監督站是否有針對性地編制監督計劃;在開工前是否對項目經理、總監等人員進行監督交底。是 否是 否30區質量監督站是否將專項施工方案中的結構設計及專家審查論證、基坑支護
41、工程的質量檢測和驗收、基坑開挖各階段的驗收、基坑變形控制觀測、高大模板及其支架的承載能力、剛度和穩定性等列為重點監督內容。是 否31區安全監督站應將經論證的專項施工方案中有關安全施工技術監控措施的落實、基坑工程的施工準備評價和達標評價、高大模板專項工程安全檢查評分和分項驗收等列為重點監督內容是 否32高大模板工程驗收時監督負責人是否到場監督。是 否33現 場安全隱患的檢查及整改情況檢查人員簽名檢查日期文明施工工程名稱層數/面積施工單位形象進度序號檢查項目檢查內容自查自糾情況工地自檢企業復檢監理檢查1現場圍擋在建成區主要路段的工地周圍未設置高于2.5m的圍擋;一般路段的工地周圍未設置高于1.8m
42、的圍擋;圍擋材料是否堅固、穩定、整潔、美觀;圍擋沿工地四周連續設置;是否建立了文明施工專項方案。2封閉管理施工現場進出口設大門、門衛和門衛制度;進入施工現場佩戴工作卡;門頭未設置企業標志。3施工現場工地主干道做硬化處理;道路是否暢通、排水設施通暢;有否防止泥漿、污水、廢水外流或堵塞下水道和排水河道措施;工地有否積水;工地應設置吸煙處、禁止隨意吸煙;溫暖季節應布置綠化。4材料堆放建筑材料、構件、料具按總平面布局堆放;料堆掛名稱、品種、規格等標牌;堆放整齊;建筑垃圾堆放整齊、標出名稱、品種;易燃易爆物品分類存放。5現場住宿宿舍人均居住面積超過2平方米;每房間人數不得超過25人;在建工程不得兼作住宿
43、;宿舍不得使用易燃材料建造;宿舍檐口高度應大于2.8米,門和主要通道寬應大于1.2米;窗戶面積大于宿舍面積1/5; 施工作業區與辦公、生活區應明顯劃分;要制定生活區管理制度、衛生管理制度、治安防范管理制度;宿舍有否消暑和防蚊叮蟲咬措施;床鋪、生活用品放置整齊;宿舍周圍環境應衛生、安全,有良好通風;地面硬化是否符合要求。6治安綜合治理生活區給工人設置學習和娛樂場所;建立治安保衛制度、責任分解到人;治安防范措施落實,能防止發生失盜事件。7標牌大門口處掛五牌一圖;標牌規范、整齊;正確掛設安全標語;設宣傳欄、讀報欄、黑板報。8生活設施廁所應按規定建造化糞池;食堂符合衛生要求;宿舍必須設置男女淋浴、廁所
44、;按每25人至少設置1個淋浴位置和一個廁所蹲位;建立衛生責任制;定期進行消毒,滅蠅蛆;保證供應衛生飲水;及時清理生活垃圾;宿舍用電是否符合用電安全要求。 9保健急救設置保健醫藥箱和急救器材;開展衛生防病宣傳教育。10社區服務建立并落實施工不擾民措施。施工項目部自檢:檢查人簽名:時間:施工企業復檢:檢查人簽名:時間: (蓋章)項目監理部門檢查及監督:檢查人簽名:時間:注:自查自糾情況需詳細填寫存在問題內容和整改落實情況。施工現場消防專項檢查評分表工程名稱:序號檢查項目扣分標準應得分數扣減分數實得分數1保 證 項 目防火制度無消防管理制度或扣10分無施工材料和化學危險品倉庫管理制度扣10分無防火檢
45、查制度扣10分無動火作業審批制度扣10分以上制度內容缺乏針對性或不全面的扣5分外包隊伍沒有簽訂防火安全協議書扣5分無組織消防演練扣5分152生活區防火宿舍區內隨處生火煮食的扣10分生活區內大量存放易燃易爆物品的扣10分生活區沒有按規定配備消防器材的扣8分工人起居房間內亂拖亂接簡易插座扣5分電線沒有按要求套管敷設扣5分工棚沒有按規定落實防雷設施扣5分室內燈具離地面高度低于2.4M扣3分153現場防火施工現場無消防設施或無滅火器材的扣10分滅火器材配置數量或間距不符合要求扣5分動火作業無監護扣5分動火作業無領取用火許可證扣3分在施工現場非吸煙區吸煙扣3分104焊接防火焊割現場沒有配備滅火器材扣10
46、分電焊機沒有防雨棚(罩)扣5分焊割部位與氧氣瓶、乙炔瓶、乙炔發生器以及各種易燃、可燃材料無作隔離的扣5分氧氣瓶、乙炔瓶間距小于5M,或與明火之間間距小于10M,或放于焊割部位下方,或放于高低壓架空線路下方、變壓器旁的扣5分焊割與油漆、噴漆、脫漆、木工等易燃操作同時間、同部位上下交叉作業的扣5分乙炔瓶、氧氣瓶平放臥倒使用,或受曝曬的扣3分乙炔瓶、氧氣瓶沒有防撞擊措施的扣3分在高空焊割無采取措施控制火花濺落的扣3分105電氣防火使用銅絲、鐵絲代替保險絲的扣10分電線截面未能滿足用電方案或用電設備荷載要求的扣8分施工現場私自使用電爐、電熱器具的扣5分避雷針接點不牢固或接地電阻大于10歐姆的扣5分10
47、小 計60施工現場消防專項檢查評分表工程名稱:序號檢查項目扣分標準應得分數扣減分數實得分數6一 般 項 目高層施工防火20層(含20層)以上高層施工沒有設置高壓水泵扣10分工程內臨時消火栓的充實水柱未能到達工程內任何部位而又沒有按規定配備滅火器的扣10分大樓底層沒有設儲水池或儲水池體積不足20立方米的扣8分動火作業審批制度中無明確工程各部位動火等級的扣5分消防水槍噴嘴口徑小于19毫扣5分107防火設施檢查記錄無按制度執行動火審批手續扣10分動火作業審批記錄不全扣5分防火檢查記錄不全扣5分無進行消防安全技術措施交底扣5分108倉庫防火存放易燃液體、氣體場所無采用防爆型電器設備及照明工具的扣5分油
48、漆庫與調料間無分開設置扣5分庫存物品無分類、分垛存儲或主要通道寬度不足2M的扣3分庫房照明燈具超過60瓦或未做到人走斷電、鎖門的扣5分在庫房內吸煙或使用明火的扣10分生石灰、石灰粉沒有遠離可燃材料堆放扣5分乙炔發生器、乙炔瓶、液化石油氣罐和氧氣瓶在新建、維修工程內存放,無設置專用房間單獨分開存放或無設專人管理或沒有滅火器材和防火標志的扣5分1010地下室防火地下室用電線路無應用絕緣材料架空敷設或潮濕地段或滲水部位無采用防潮燈具的扣8分疏散走道、樓梯、坡道不通暢或堆放材料、機具的扣5分火災事故照明和疏散指示燈不能自動投合使用扣5分在地下工程內使用或存放中壓式乙炔發生器扣5分沒有制定應急的疏散計劃
49、扣5分10小 計40合計檢查人: 檢查日期: 年 月 日結構實體混凝土強度檢驗表工程名稱: 施工單位:約定檢測方法序號結構部位設計強度等 級實體強度值判 定12345結論與處理意見檢驗人: 監理工程師:項目經理: 年 月 日砌體材料質量抽檢、分部工程驗收檢查及給排水分部工程施工圖送審情況檢查表 工程名稱施工單位形象進度水工程是否已進場檢測項目檢查要求檢查結果未發現不符合不符合砌體結構用磚質量抽檢按檢測中心提出的抽樣數量在現場抽取磚送到檢測中心,要求按省統一用表GD、GD的格式出具含尺寸數據的檢測報告。其中灰砂磚抽樣數量為第組50塊。有抽檢無抽檢/分部工程質量驗收情況根據工程形象進度,檢查上一階段(主要是基礎分部和主體分部)工程完成后,有否及時作分部工程驗收并作記錄。給排水、消防工程施工圖審查情況重點檢查自2005年8月1日起報建且須審圖的建筑工程,明確其給排水、消防工程施工圖亦須送審。最遲出具審圖批準書的時間為水工程進場施工的時間。整改要求詳見所附整改通知(編號: )檢驗人: 監理工程師:項目經理: 年 月 日特種作業持證上崗率落實情況檢查匯總表工程名稱施工單位監理單位抽查工種是否達到100所持證件 發證部門監理有否督促檢查檢查人員簽字要求:重點抽查架子工,垂直運輸設備安裝、操作人員持證上崗率